Universal Remote Control TOTAL CONTROL FX-1 Provozní pokyny Strana 1

Procházejte online nebo si stáhněte Provozní pokyny pro Dálková ovládání Universal Remote Control TOTAL CONTROL FX-1. Universal Remote Control TOTAL CONTROL FX-1 Operating instructions Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 14
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
POLAR-CONTROLLER
TM
Operating Instructions
P/N 100101 (120 VAC)
P/N 100106 (230 VAC)
Zobrazit stránku 0
1 2 3 4 5 6 ... 13 14

Shrnutí obsahu

Strany 1 - POLAR-CONTROLLER

POLAR-CONTROLLERTM Operating Instructions P/N 100101 (120 VAC) P/N 100106 (230 VAC)

Strany 2

9 2. DMX Addressing Each DMX’d unit will occupy a unique DMX address on the DMX chain. By adjusting the dip switches on the side of the fog machine

Strany 3 - Contents

10 0 – 49% = Off 50 – 100% = On 6. Service and Maintenance 6.1 Emptying the tray Take care to be sure drip pan is in place. Empty it

Strany 4 - 2. Accessories

11 7. Technical Data Polar ControllerTM Technical Data P/N 100101 (230V P/N 100106) Type of Fog Thick, white, dry, low-ground fog Weight w/fogger

Strany 5 - 4. Safety instructions

12 8. Limited Warranty Conditions This limited warranty guarantees to the original purchaser that this product shall be free of defects in mat

Strany 6 - Selecting the Location

13 days of receipt, CITC will cover the cost of returning the repaired unit to the customer. 4. Limited warranty services do not cause an extension

Strany 7 - Operating the machine

1 Thank you for purchasing this POLAR CONTROLLERTM  As you will notice from the table of contents, the manual for your new product is quite ext

Strany 8 - Shut down

2 Contents 1. Set of Equipment Supplied 3 2. Accessories 3 3. Description 4

Strany 9

3 1. Set of Equipment Supplied  1 Polar ControllerTM w/DMX On board  1 Remote Control Unit  Double-hose outlet manifold  Two 5” X 8ft fog

Strany 10

4 3. Description of the POLAR CONTROLLERTM The POLAR CONTROLLERTM is CITC’s new low-ground fogging system. No CO2, no dry ice, and no separate fog m

Strany 11 - Service and Maintenance

5 5. Operating the POLAR CONTROLLERTM 5.1 Selecting the Location Secure a good location for the machine to rest solidly on the floor separated

Strany 12 - Technical Data

6 position. Lay the tube along the floor keeping it on the floor away from any hot lights. Do not bend the tubes into sharp 90o angles. The straighte

Strany 13 - Limited Warranty Conditions

7 backpressure and cause a buildup of residue. Backpressure can cause a severe amount of condensation and will create problems for you later on down t

Strany 14

8 o If the fog is wet this is usually caused by turning up the volume too high. Only operate at 100% (below blast on the remote control) or below 7

Komentáře k této Příručce

Žádné komentáře